Measured Indicators, Measuring units, Methodologies for measurement
Manual sampling:
Measured Indicators: SO2 , NO2 , Pb, Cd, TSP, ФПЧ /10/, meteorological parameters
Measuring units: µg/m3 , mg/m3 , m/s, mm Hg, 0C.
The level gases of SO2 and NO2 in the atmospheric air are determined in accordance with BDS 17.2.4.17-83, BDS 17.2.4.22-83.
The content of dust is determined according to method in accordance with BDS 17.2.4.20-83, the fine particulate matter - BDS 17.2.4.20-83. The content of lead и cadmium is determined according to the method of atomic absorption in accordance with methodology approved by the minister of MOEW.
Automaed stationary station for air control
Measured Indicators |
signify |
Measuring units |
carbon monoxide |
CO |
mg/m3 |
ozone |
O3 |
µg/m3 |
sulphur dioxide |
SO2 |
µg/m3 |
nitrogen monoxide |
NO |
µg/m3 |
nitrogen dioxide |
NO2 |
µg/m3 |
PM<10 |
Прах |
µg/m3 |
ammonia |
NH3 |
mg/m3 |
hydrogen sulphide |
H2S |
mg/m3 |
benzole |
C6H6 |
µg/m3 |
Wind speed |
|
m/s |
Wind direction |
|
- |
atmospheric pressure |
|
mBar |
solar radiation |
|
W/m2 |
temperature |
t
|
0C |
Relative humidity |
|
% |
The pollutants are measured according to methodologies approved by the minister of MOEW.
Description of measuring instruments
Manual sampling:
The sampling is performed by “Bravo”, “Strolein” instruments.
Spectrometer UV/VIS Lambda 2S PERKIN ELMER
MW digestion system MILESTONE
Atomic absorption spectrophotometer UNICAM 939
automaed stationary station for air control
Analyser |
Measured Indicators |
Principle of measurement |
48
C |
carbon monoxide |
absorption of infra-rays with correlation |
MLU 400 |
ozone |
absorption of UV rays |
MLU |
sulphur dioxide |
Fluorescence |
MLU 200A |
nitrogen monoxide nitrogen dioxide |
Chemilumeniscence |
FH62I-R |
dust |
absorption of ß rays |
MLU 201A |
ammonia |
Chemilumeniscence |
MLU 101A |
Сероводород |
Fluorescence |
APHA 360 |
MNVOCs |
Flame ionization |
GC 855 |
benzole |
Gas chromatography |
|